    VK-ZPDU-V3 series Smart PDU function

    1. Double-precision high-tech energy calculation can provide very accurate power metering and power factor data for a single socket.

    2. Color LCD Display

     The color LCD display screen is used to display the information of voltage, current, power factor, electric energy, IP address, temperature and humidity, CAN/485 hardware address and so on.

    3. Provides real-time power monitoring

    By using efficient data processing, it can not only provide real-time data such as input current, voltage, power, power factor, electric energy, frequency and so on. PDU, with the detection function of each socket, it can also provide the power output of each socket, and can display the current, power factor and electric energy of each socket in real time. Provides the function of graph image display.

    4. Can switch on/off single socket remotely

    The PDU, with each control function can control each socket through HTTPSNMPSSH and other network protocols to realize remote control function. At the same time, various protocols can provide encryption SSL, make remote control more secure and reliable.

    5.PDU socket metering function

    It can provide users with the basis to realize PUE accurate calculation, and can plan and optimize the energy consumption of the data center, thus providing the basis for the data center managers to reduce the cost of load balancing and setting IT environment.

    6. Users can customize the alarm threshold, which can warn potential circuit overload by real-time local and remote alarm, thus reducing the risk.

    7. Advanced switch function, it can realize user-defined logic control, can independently realize the switch action and schedule of each plug seat, and can take intelligent action according to the change of environment.

    According to the current threshold and temperature threshold, the user can control the PDU output switch, and give a variety of alarm tips. The socket has the function of parameter replication, setting the parameters of one socket, can quickly copy to other sockets. At the same time PDU, each socket can switch the socket according to the time or time set by the user, and has 20 user-defined time or time editing functions to meet the user's complex logic control requirements.

    8. Socket sort delay to avoid circuit overload and customize time

    When switching socket or power on, the time interval between sockets can be set flexibly, which is beneficial to the stable operation of load and avoid surge.

    9. Socket group management function

    PDU, users with single socket management can customize socket grouping, and flexible socket grouping is beneficial to user classification management of socket. At the same time, the hardware is also independently divided into 3 groups, each group of 8 sockets. Electrical isolation is also achieved for every 8 bit socket of the three-phase PDU.

    Users can access and configure multiple access controls through secure WebSNMPSSH or Telnet interfaces for ease of operation and integration.

    11. Provision of isolation of 2 temperature/humidity sensors ,3 inputs and 1 output port

    12. Provide isolation CANbusRS485 serial networking

    This PDU not only provides the common SNMP management function of data center, but also can collect data and control equipment through serial mode such as CAN bus and RS485. In small and medium-sized data centers or environments without network